MAF Connector Replacement

Step 12

Install the orange seal in the connector and you're done. One last TIP: Before re-connecting it to the MAF sensor, squeeze some dialectric compound into each pin. This will help to make sure you have a corrosion-free, watertight connection – which is extremely important with low voltage, variable-feedback sensors. It helps to keep running gremlins from raising their mischievous heads.